Septic Plumbing Lake Wales

As a septic system owner, you may want to try your best to stay septic safe. This is more important if you are around the opening of the septic tank. As a matter of fact, you should know all of the important safety precautions that should be taken prior to working on the septic system.

Follow the safety tips given below:

1. Septic tank lid
Make sure that the access port of your tank is covered with a solid lid. Make sure that the lid is strong enough. Kids should not be able to open it. If you have no idea as to how to install the system, you can call a professional for help. The company will be more than happy to help with the inspection.

2. The tank opening
You should never lean over the septic tank opening. The reason is that the gasses that come out of the tank may knock you out. You may also fall in the tank, which may prove fatal.

3. Driving Over The septic system
Driving heavy machine on the ground where the tank system is buried is not a good idea. Actually, you may have to bear heavy costs in order to get the broken pipes repaired. So, make sure you don’t drive heavy equipment or machinery on the ground where you buried the tank system.

Contact Info:
Name: Billy Fowler
Email: info@asapadvancedseptic.com
Organization: ASAP Advanced Septic & Drainage, Inc.
Address: 5011 E Busch Blvd, Tampa, FL 33617
Phone: (813) 986-6070

Safety Tips For Working Around A Septic Tank System

Septic Systems For Dummies

Septic tank problems often occur with systems that are onion- shaped. The liquids and solids in a septic tank are separated by a baffle that comes in the form of a ball-shaped figure, or an inner sleeve shaped skin that has hooks attached to it at the top of the inner side of the neck. However, the wear and tear in the passing years may tear off the baffle allowing it to sink in the tank. Also, the ball in the receptacle may be knocked loose and disentangle itself. Most septic system problems begin with these two scenarios because liquid and solid wastes combine as they go through the soak away and this may cause a blockage.

One way to address septic tank problems especially if the baffle collapsed is for a homeowner to set-up a filter for his tank. Filters like these can be placed by a homeowner inside an outlet pipe, so that the septic system can function more effectively not to mention that it can save one a significant amount of money. However, if problems are more acute, a homeowner has no other recourse but to replace his or her old septic tank. Another concern that is related to cesspit are open, loose, or worn-out manhole covers.

Other problems that can be resolved yourself are solids blocking the soakway. A T-bar can used to unblock the passage. This very basic baffle is made of clay, but for those who want to replace it with a current version. The replacements units are generally reproduced in plastic to save on cost. However, one has to be careful with these baffles because if they are not correctly installed, the solids will still enter the soakway unhampered causing more damage. A homeowner would perhaps consider buying septic tank filler for him to solve his septic tank problems himself and save on the installation costs. On the other hand, this type of job is often better handled by a professional who isn't afraid to get his hands dirty.

 

Tips on Preventing Septic System Back-up

Sewer Snake

Two Components

Class 4 septic systems are divided into two components, the septic tank and the septic field or leaching bed. Waste is piped out of the house into the septic tank, which is essentially a water clarification tank, in which anaerobic bacteria break the waste down into solids (sludge), liquid effluent, and scum.

Septic System

The solids settle to the bottom, the scum floats to the top and the liquid effluent flows through an outlet pipe into a distribution chamber, where it is directed to the septic field. The septic field is an effluent water disposal system, where the liquid is channeled through perforated pipes to different parts of a field of loose gravel.

Septic tank materials that initially float in the scum layer are kept out of the drainage system by an outflow tee or baffle. If the tank is not pumped regularly, the level of solids can rise, and if it approaches the level of the outflow tee, scum and solids can proceed out into the drainage system, clogging the pipes and gravel - and eventually preventing the absorption of the water by the surrounding earth.

A Class 5 septic system is a holding tank for the storage of sewage at the site where it is produced. A typical holding tank system is comprised of a single compartment tank with a pump-out stack and an audible or visual warning device to alert the homeowner when the tank requires emptying. A holding tank is costly to operate, places restrictions of the owner, and is dependent on Class 7 (hauled) sewage system for waste collection and disposal.

General Guidelines for Purchasers

  • If the system is 5-7 years old and has never been pumped it is unlikely that there are serious problems.
  • If there is no record of the system having been pumped but the owner has a vague recollection of pumping the system at some time in the distant past, figure that it has never been pumped.
  • If the system is over 10 years old and has never been pumped, it is possible that there has been some damage to the septic field, and if it's not been pumped for over 15 years it is quite likely.
  • Flushing dye through the system looks good but will only indicate systems that are already seriously clogged, in which case there should already be more obvious signs.
  • Flushing dye may not indicate serious defects or indicate systems that are close to failure but still functional.
  • If you are on a septic system, adding a bedroom, even without adding a bathroom, may mean having to increase the size of the tank and drainage field.

The only way to make an accurate determination of the system is to have a licensed septic contractor perform a tank, distribution chamber and field inspection.

What is Involved in Septic Tank Pumping?

Sepsis Infection

Two Components

Class 4 septic systems are divided into two components, the septic tank and the septic field or leaching bed. Waste is piped out of the house into the septic tank, which is essentially a water clarification tank, in which anaerobic bacteria break the waste down into solids (sludge), liquid effluent, and scum.

Septic System

The solids settle to the bottom, the scum floats to the top and the liquid effluent flows through an outlet pipe into a distribution chamber, where it is directed to the septic field. The septic field is an effluent water disposal system, where the liquid is channeled through perforated pipes to different parts of a field of loose gravel.

Septic tank materials that initially float in the scum layer are kept out of the drainage system by an outflow tee or baffle. If the tank is not pumped regularly, the level of solids can rise, and if it approaches the level of the outflow tee, scum and solids can proceed out into the drainage system, clogging the pipes and gravel - and eventually preventing the absorption of the water by the surrounding earth.

A Class 5 septic system is a holding tank for the storage of sewage at the site where it is produced. A typical holding tank system is comprised of a single compartment tank with a pump-out stack and an audible or visual warning device to alert the homeowner when the tank requires emptying. A holding tank is costly to operate, places restrictions of the owner, and is dependent on Class 7 (hauled) sewage system for waste collection and disposal.

General Guidelines for Purchasers

  • If the system is 5-7 years old and has never been pumped it is unlikely that there are serious problems.
  • If there is no record of the system having been pumped but the owner has a vague recollection of pumping the system at some time in the distant past, figure that it has never been pumped.
  • If the system is over 10 years old and has never been pumped, it is possible that there has been some damage to the septic field, and if it's not been pumped for over 15 years it is quite likely.
  • Flushing dye through the system looks good but will only indicate systems that are already seriously clogged, in which case there should already be more obvious signs.
  • Flushing dye may not indicate serious defects or indicate systems that are close to failure but still functional.
  • If you are on a septic system, adding a bedroom, even without adding a bathroom, may mean having to increase the size of the tank and drainage field.

The only way to make an accurate determination of the system is to have a licensed septic contractor perform a tank, distribution chamber and field inspection.

Overview On Septic Systems And the Inspection Process

Replace Septic Tank

Septic tank systems become clogged with roots in the leach lines, leach field, drain field or seepage field, causing backup of wastewater into the house. The inexpensive fix is to use copper sulfate through an installed cleanout or septic field pump.

Septic tank systems

Septic tank systems do not last forever and replacing one is a very expensive proposition. If your house is connected to the city sewer system, then you do not have a septic tank. A septic tank can be described as your very own little sewage treatment plant. There are three basic elements of a septic system:

  1. The septic line that carries sewage and waste water from your house to the tank. There is usually a cleanout plug at the house-end it so that you can run a snake down it to remove obstructions.
  2. The septic tank itself where sewage is held while undergoing decomposition. This is underground, probably under a grassy area, and has a cover that is usually buried in residential installations.
  3. The leach field, also referred to as a drain field or seepage field. This is a branching network of underground porous trenches, pipes or something similar that carries the clear liquid from the septic tank throughout adjacent soil where it is absorbed.

A clogged leach field

Eventually leach fields become clogged because the roots from trees and other vegetation are attracted to the nutrient-rich effluent. The roots grow through the pores intended to drain the liquid, seepage gradually slows or stops.

If sufficient pressure cannot be released through the pores of the leach field, the entire septic system cannot accept any more waste water and it backs up in the house, usually at a low point such as a shower or tub drain. If it gets that bad, you may have to replace the entire leach field. In many localities, that will require a building permit and meeting current building codes, which means replacing the entire septic system, which is expensive, etc.

Kill roots with copper sulfate

Since this is obviously something to avoid, you can often extend the life of the old system by taking action when sewage flow has slowed, but not completely stopped. Copper sulfate kills roots. If it can be placed into the system so that it will flow through the leach field, the roots will die (but not the plants) and waste water will begin to flow more freely again after a few weeks. In many systems, this isn’t as easy as it sounds, because copper sulfate is so heavy that it will settle to the bottom of the septic tank unless inserted into the leach line leading from the tank. If you have a cleanout or other access there, you’re all set, but many residential systems do not. I prefer the crystal form over the powder because it's easier to handle, cheaper and dissolves more slowly, .

Install a leach line cleanout

If necessary, it is not very expensive to have a cleanout installed in the leach line expressly for the purpose of adding copper sulfate periodically. If that still doesn’t quite work, or if you want to be sure the stuff is going to flow more quickly, you can pump it through the leach field.

It is possible to install a pump on the leach line cleanout between the septic tank and the leach field. It can be buried below ground level or installed above ground and concealed with landscape bushes. The pump turns on and off automatically to maintain a slight pressure on the waste water, pushing it through the pores of the seepage field. Adding copper sulfate at intervals through a cleanout at this point is effective to drive the chemical towards the offending roots.

Killing the roots may extend the life of the septic system a few years, but it will ultimately need to be replaced with a completely modern one—unless you can successfully lobby for a neighborhood hook-up, of course.

So, these are a few precautions that you may want to take if you are going to work on a septic tank system. This is important should you want to keep you and your family safe around the system. When in doubt, it’s a good idea to call a local septic service in Lake Wales . Hopefully, these tips will help.

SEPTIC TANK CARE | WHO TO CALL FOR SERVICE IN Lake Wales

Two Components

Class 4 septic systems are divided into two components, the septic tank and the septic field or leaching bed. Waste is piped out of the house into the septic tank, which is essentially a water clarification tank, in which anaerobic bacteria break the waste down into solids (sludge), liquid effluent, and scum.

Septic System

The solids settle to the bottom, the scum floats to the top and the liquid effluent flows through an outlet pipe into a distribution chamber, where it is directed to the septic field. The septic field is an effluent water disposal system, where the liquid is channeled through perforated pipes to different parts of a field of loose gravel.

Septic tank materials that initially float in the scum layer are kept out of the drainage system by an outflow tee or baffle. If the tank is not pumped regularly, the level of solids can rise, and if it approaches the level of the outflow tee, scum and solids can proceed out into the drainage system, clogging the pipes and gravel - and eventually preventing the absorption of the water by the surrounding earth.

A Class 5 septic system is a holding tank for the storage of sewage at the site where it is produced. A typical holding tank system is comprised of a single compartment tank with a pump-out stack and an audible or visual warning device to alert the homeowner when the tank requires emptying. A holding tank is costly to operate, places restrictions of the owner, and is dependent on Class 7 (hauled) sewage system for waste collection and disposal.

General Guidelines for Purchasers

  • If the system is 5-7 years old and has never been pumped it is unlikely that there are serious problems.
  • If there is no record of the system having been pumped but the owner has a vague recollection of pumping the system at some time in the distant past, figure that it has never been pumped.
  • If the system is over 10 years old and has never been pumped, it is possible that there has been some damage to the septic field, and if it's not been pumped for over 15 years it is quite likely.
  • Flushing dye through the system looks good but will only indicate systems that are already seriously clogged, in which case there should already be more obvious signs.
  • Flushing dye may not indicate serious defects or indicate systems that are close to failure but still functional.
  • If you are on a septic system, adding a bedroom, even without adding a bathroom, may mean having to increase the size of the tank and drainage field.

The only way to make an accurate determination of the system is to have a licensed septic contractor perform a tank, distribution chamber and field inspection.

Polk Septic System Pump Out

Home